Concrete screw W-BS steel zinc plated type P
CONCSCR-(W-BS/P)-(A2K)-TX30-15-5X50

Art.-no. 5929145015
EAN 4046777685343

Prices for customers after login

Show availability in Würth branch offices
Exclusively for trade customers

Register now and access more than 60,000 products

Ideal for fastening mounting rails, panel materials or fire-protection panels, zinc-plated steel
  • For anchorage in concrete and masonry

  • Extremely flexible application thanks to up to three effective anchorage depths

  • Fastening can be adjusted up to twice after installation, for example in order to align anchor plates or rails (please refer to the installation instructions)

  • High admissible loads

  • Very low spacing and edge distances thanks to very low expansion effect

  • Very fast and easy installation and immediate load-bearing capacity
Proof of Performance

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (∅6)

  • Seismic action, performance category C1 (∅6)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (∅5 - ∅6)

  • Fire resistance R30, R60, R90, R120 (∅5 - ∅6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (∅6)

  • Hollow-core prestressed concrete slabs C30/37 - C50/60, (∅6)

  • Fire resistance R30, R60, R90, R120


Fire resistance rating when exposed to fire according to the uniform temperature time curve in masonry (Mz, KSL, KS), and reinforced concrete, (dia. 5 and dia. 6) - expert report no 2101/173/18 - 2018

Notice

When installing with a tangential impact driver, the recommended maximum rated torque must be observed.


When used in masonry, the stone-specific installation data according to ETA-23/0196 must be observed.

Application area

Adjustment - subsequent aligning possible

Create the drill hole

Clean the drill hole

Place screw

Screw in the screw

Considered installed when the head is close fitting

Screw out the screw max. 2x each by max. 10 mm. Underlay. Screw in

Considered installed when the head is close fitting. Lining max. 10 mm. The required embedment depth must be maintained as a minimum

Locate the tensioning strand

Mark the tensioning strand and locate the next one

Mark the tensioning strands. Specify the drilling range

Create the drill hole. Observe spacing

Clean the drill hole

Screw in the screw

Considered installed when the head is close fitting. Observe the embedment depth/mirror thickness

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (∅6)

  • Seismic action, performance category C1 (∅6)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (∅5 - ∅6)

  • Fire resistance R30, R60, R90, R120 (∅5 - ∅6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (∅6)

  • Hollow-core prestressed concrete slabs C30/37 - C50/60, (∅6)

  • Fire resistance R30, R60, R90, R120


Fire resistance rating when exposed to fire according to the uniform temperature time curve in masonry (Mz, KSL, KS), and reinforced concrete, (dia. 5 and dia. 6) - expert report no 2101/173/18 - 2018

Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

Anchorages in concrete, individual fixing point with approval (∅6):


In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete)



Anchors in a redundant non-structural system in concrete, with approval:


  • In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete), (∅5 and ∅6)

  • In hollow-core prestressed concrete slabs C30/37 - C50/60, (∅6)


Anchorages in masonry with approval (∅5 - ∅6):


  • In solid calcium silicate block and perforated block

  • In solid block masonry brick


Pan head with an attractive head geometry, ideally suited for fastening medium loads in concrete and light to medium loads in masonry:


  • Fastening of e.g. mounting rails, panels, sheets, fire protection panels, handrails, metal profiles, brackets, wooden substructures etc. in in-place installation

  • Fastenings subject to seismic activity in earthquake-prone areas (only concrete)

  • Fastenings subject to exposure to fire


W-BS/S (galvanised steel) may only be used in dry indoor room conditions



For use in concrete < C20/25 and pressure-resistant natural stone (without approval)

Anchor size

5 mm

Anchor length (l)

50 mm

Attachment height (t fix 1)

15 mm

Thread diameter

6.5 mm

Nominal drill-bit diameter (d 0)

5 mm

Drill hole depth (h 1.1)

40 mm

Embedding depth (h nom1)

35 mm

Internal drive

TX30

Material

Steel

Surface

Zinc plated

Head diameter

14 mm

Through-hole in the component to be connected (d f)

7 mm

Head type

Pan head

Type description

W-BS type P

Performance data in concrete - fixing point according to ETA-16/0043
Anchor size [mm]6
C2
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0043
Length of anchor in drilled holehnom [mm]4055
Admissible centric tension load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nperm. [kN] = C20/252)1,01,9
Compressive zone
(non-cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
1,94,3
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vperm. [kN] = C20/252)3,03,3
Compressive zone
(non-cracked concrete C20/252), c ≥ 10 hef)
3,33,3
Permissible bending moment Madm [Nm]4,8
Admissible load under seismic activity performance categories C1 and C2 see European Technical Assessment ETA-16/0043C1xx
Performance data in concrete - anchors in a redundant non-structural system according to ETA-16/0128
Anchor size [mm]56
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0128
Length of anchor in drilled holehnom [mm]353555
Anchors in concrete in a non-structural system based on a redundant design3)Nperm. [kN] ≥ C20/250,60,63.64)
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vperm. [kN] = C20/252)2,02,03,3
Compressive zone (non-cracked concrete C20/252), c ≥ 10 hef)2,12,83,3
Permissible bending moment Madm [Nm]2,54,8
Performance data in hollow-core prestressed concrete ceilings - anchors in a redundant non-structural system according to ETA-16/0128
Anchor size [mm]6
Mirror thickness [mm]≥ 25≥ 30≥ 35
Anchors in a redundant non-structural system in hollow-core prestressed concrete ceilings5)Fperm. [kN] 0,40,81,2
Installation parameters in concrete
Anchor size [mm]56
Nominal drill diameterd0 [mm]56
Diameter of cutting edgesdcut ≤ [mm]5,406,40
Drill hole depthh1 ≥ [mm]40404560
Through hole in the component being connecteddf ≤ [mm]78
Internal drive TX30TX30
Head diameterdh [mm]1415
Screw-head heighthh [mm]3,23,5
Max. rated torque of tangential impact screwdriverTimp,max [Nm]110160
Nominal length of thread engagementhnom [mm]351)351)4055
Minimum axis distance smin [mm]353540
Axis distancescr,N [mm]818193132
Minimum edge distancecmin [mm]353540
Edge distanceccr,N [mm]40,540,546,566
Minimum member thicknesshmin [mm]8080
Installation parameters in pre-loaded hollow ceiling panels
Anchor size [mm]6
Spacing between tensioning strands and drilled hole ap ≥ [mm]50
Nominal drill diameterd0 [mm]6
Through hole in the component being connecteddf ≤ [mm]8
Minimum axis distance smin [mm]100
Minimum edge distancecmin [mm]100
Minimum spacing between the groups of anchors amin [mm]100
Spacing between cavity axes lc ≥ [mm]100
Spacing between tensioning strands lp ≥ [mm]100
Performance data of an individual anchor in solid and perforated block masonry according to ETA-23/0196
Anchor sizeNominal length of thread engagementAdmissible tensile loadAdmissible shear loadMin. edge distanceMin. spacingDistance from jointsMax. torque for manual installationMax. torque for installation with drill/driverInstallation using tangential impact driver
Solid calcium silicate block KS NF in accordance with EN 771-2:2015-11
KS 20 -2.0 - NF - 240 x 115 x 71 mm, stone raw density ρ ≥ 2.0 kg/dm3, stone compressive strength fmean = 26 N/mm2, minimum wall thickness hmin = 240 mm
Silka XL solid calcium silicate block KS 12DF in accordance with DIN EN 771-2:2015-11
KS- R (P) -2.0 - 12DF - 498 x 175 x 148 mm, stone raw density ρ ≥ 1.8 kg/dm3, stone compressive strength fmean = 14 N/mm2, minimum wall thickness hmin = 175 mm
Hollow calcium silicate block KS L, 3DF in accordance with DIN EN 771-2:2015-11
SWKV KSL 12 - 1.6 - 3DF - 240 x 175 x 113 mm, stone raw density ρ ≥ 1.5 kg/dm3, stone compressive strength fmean = 17 N/mm2, minimum wall thickness hmin = 175 mm
Masonry brick Mz in accordance with DIN EN 771-1:2015-11
Mz 20 - 2.0 - NF - 240 x 115 x 75 mm, stone raw density ρ ≥ 2.1 kg/dm3, stone compressive strength fmean = 21 N/mm2, minimum wall thickness hmin = 240 mm
5350,660,91808040806
6350,660,91808040801010
6551,172,378080408010 185
5350,310,465880355868100
6350,310,46588035581110100
6550,310,465880355811 100
5350,460,68080358024
6350,460,68080358039
6550,460,68080358039
hnomNadmVadmcminsmin, ||= smin, cj⊥cj ||TinstTinstTimp,max
[mm][mm][kN][kN][mm][mm][mm][mm][Nm][Nm][Nm]
53510,94808035806 185
6350,890,94808035801110185
6551,40,948080358011 185
General installation parameters in masonry:
Anchor sizeDiameter56
Drill hole depthh0[mm]555575
Through hole in the fixturedf[mm]78
Nominal length of thread engagementhnomhnom1hnom1hnom2
[mm]353555
Nominal drill diameterd0[mm]56
Diameter of cutting edgesdcut[mm]5,46,4
Additional accessory:
 
Product
Description
Quantity
PU
Price
/PU
Blow-out bulb for drill hole cleaning

BLWOUTBULB-F.CLN

For cleaning drill holes with a smaller diameter
x 1 pcs
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information